↓ Skip to main content

Quantification of macular perfusion in healthy children using optical coherence tomography angiography

Overview of attention for article published in International Journal of Retina and Vitreous , October 2021
Altmetric Badge

About this Attention Score

  • Average Attention Score compared to outputs of the same age
  • Above-average Attention Score compared to outputs of the same age and source (55th percentile)

Mentioned by

twitter
2 X users

Citations

dimensions_citation
7 Dimensions

Readers on

mendeley
9 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
Quantification of macular perfusion in healthy children using optical coherence tomography angiography
Published in
International Journal of Retina and Vitreous , October 2021
DOI 10.1186/s40942-021-00328-2
Pubmed ID
Authors

Fariba Ghassemi, Vahid Hatami, Farhad Salari, Fatemeh Bazvand, Hadi Shamouli, Masoumeh Mohebbi, Siamak Sabour

Abstract

This study aimed at defining the variance of vessel density (VD) characteristics in the macula of children with normal eyes. This was a cross-sectional study in which subjects with normal eyes aged 3-18 years were enrolled. The macula was scanned by optical coherence tomography angiography (OCTA). Four age groups as under 7 years, 7-10 years, 11-14 years and more than 14 years of age were defined. The influences of age, gender, and body mass index on VD were analyzed. A total of 108 normal eyes from 54 participants with a mean age of 10.9 years were enrolled in the study. At the superficial and deep retina capillary plexus (SCP and DCP) and choriocapillaris (CC), respectively, the mean VD of the fovea was 20.10%, 36.99%, and 75.67%; at parafovea, these measurements were 53.12%, 55.81%, and 69.76%; and at perifovea, these measures were 51.38%, 52.46%, and 73.47%. The median foveal avascular zone (FAZ) was 0.30 mm2. No significant differences between superior-hemi VD and inferior-hemi VD were found in the studied plexuses. The VD at parafovea and perifovea CC differed significantly between groups. There was no variation in VD of macular retina and CC between eyes or sex. FAZ areas were different between genders. No difference between eyes and genders in the retina and CC VD of macular area was noted. FAZ area was larger in male. Even though this is not a longitudinal study, it may provide us with hints about macular vascular development during puberty and clinical implications of OCTA in children.

X Demographics

X Demographics

The data shown below were collected from the profiles of 2 X users who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 9 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 9 100%

Demographic breakdown

Readers by professional status Count As %
Student > Bachelor 3 33%
Unspecified 1 11%
Student > Doctoral Student 1 11%
Professor 1 11%
Student > Ph. D. Student 1 11%
Other 1 11%
Unknown 1 11%
Readers by discipline Count As %
Medicine and Dentistry 3 33%
Unspecified 1 11%
Economics, Econometrics and Finance 1 11%
Nursing and Health Professions 1 11%
Sports and Recreations 1 11%
Other 1 11%
Unknown 1 11%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 2. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 13 October 2021.
All research outputs
#16,734,944
of 25,392,582 outputs
Outputs from International Journal of Retina and Vitreous
#94
of 262 outputs
Outputs of similar age
#247,586
of 436,513 outputs
Outputs of similar age from International Journal of Retina and Vitreous
#6
of 18 outputs
Altmetric has tracked 25,392,582 research outputs across all sources so far. This one is in the 32nd percentile – i.e., 32% of other outputs scored the same or lower than it.
So far Altmetric has tracked 262 research outputs from this source. They receive a mean Attention Score of 3.8. This one has gotten more attention than average, scoring higher than 60% of its peers.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 436,513 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 39th percentile – i.e., 39% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 18 others from the same source and published within six weeks on either side of this one. This one has gotten more attention than average, scoring higher than 55% of its contemporaries.