↓ Skip to main content

Management of anterior chamber dislocation of a dexamethasone intravitreal implant: a case report

Overview of attention for article published in Journal of Medical Case Reports, October 2016
Altmetric Badge

Mentioned by

twitter
1 X user

Citations

dimensions_citation
22 Dimensions

Readers on

mendeley
36 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
Management of anterior chamber dislocation of a dexamethasone intravitreal implant: a case report
Published in
Journal of Medical Case Reports, October 2016
DOI 10.1186/s13256-016-1077-2
Pubmed ID
Authors

Fernanda Pacella, Enzo Agostinelli, Sandra Cinzia Carlesimo, Marcella Nebbioso, Roberto Secondi, Michele Forastiere, Elena Pacella

Abstract

Ozurdex is a 700 mcg dexamethasone intravitreal implant, approved for the management of macular edema secondary to retinal vein occlusion, and other related pathoglogiesAnterior chamber dislocation of Ozurdex represents an uncommon complication of the intravitreal injection, which can be managed by repositioning the implant into the vitreous cavity. We describe the case of a successful repositioning of an Ozurdex implant by mobilization and subsequent balanced saline solution injection in the anterior chamber. An 83-year-old white woman presented to our Emergency Unit complaining of pain and vision loss in herright eye lasting a week. Her anamnesis revealed a history of persistent cystoid macular edema after phacoemulsification with scleral-fixated posterior chamber intraocular lens implantation, recently treated with an intravitreal Ozurdex implant. She also took a long-distance flight 2 days after the injection. An anterior segment examination showed corneal edema and the rod implant adherent to corneal endothelium. To avoid corneal decompensation, we opted for a implant repositioning. Under topical anesthesia, a 30-gauge needle was introduced through a limbar incisionto mobilize the dislocated rod. Balanced saline solution was injected, with a successful repositioning of the implant into the vitreous cavity. Topical 5 % hypertonic saline solution and 0.2 % betamethasone associated with 0.5 % chloramphenicol drops were administered four times a day. To prevent redislocation of the Ozurdex implant, she was instructed to avoid prone position, any kind of physical effort, and not to undertake long-distance flights during the first postoperative week. One week after surgery, an anterior segment examination showed an improvement of corneal edema. Funduscopy showed that the Ozurdex implant was settled into the vitreous cavity. Anterior chamber dislocation of Ozurdex from the vitreous cavity is rare. In our patient, in addition to the posterior capsule tearing, the long-distance flight could have contributed to implant dislocation. Repositioning of the implant is necessary to avoid endothelial decompensation. It can be carried out by using saline balanced solution with the same efficacy as other surgical procedures reported in the literature. A possible disadvantage of this procedure could be implant migration.

X Demographics

X Demographics

The data shown below were collected from the profile of 1 X user who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 36 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 36 100%

Demographic breakdown

Readers by professional status Count As %
Student > Doctoral Student 4 11%
Student > Ph. D. Student 4 11%
Researcher 4 11%
Student > Bachelor 3 8%
Student > Master 2 6%
Other 5 14%
Unknown 14 39%
Readers by discipline Count As %
Medicine and Dentistry 14 39%
Nursing and Health Professions 2 6%
Chemistry 2 6%
Economics, Econometrics and Finance 1 3%
Psychology 1 3%
Other 1 3%
Unknown 15 42%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 1. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 17 October 2016.
All research outputs
#18,475,157
of 22,893,031 outputs
Outputs from Journal of Medical Case Reports
#2,267
of 3,932 outputs
Outputs of similar age
#241,702
of 319,475 outputs
Outputs of similar age from Journal of Medical Case Reports
#46
of 89 outputs
Altmetric has tracked 22,893,031 research outputs across all sources so far. This one is in the 11th percentile – i.e., 11% of other outputs scored the same or lower than it.
So far Altmetric has tracked 3,932 research outputs from this source. They receive a mean Attention Score of 3.9. This one is in the 11th percentile – i.e., 11% of its peers scored the same or lower than it.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 319,475 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 13th percentile – i.e., 13% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 89 others from the same source and published within six weeks on either side of this one. This one is in the 3rd percentile – i.e., 3% of its contemporaries scored the same or lower than it.