↓ Skip to main content

Estimation of optic nerve sheath diameter on an initial brain computed tomography scan can contribute prognostic information in traumatic brain injury patients

Overview of attention for article published in Critical Care, March 2013
Altmetric Badge

About this Attention Score

  • Good Attention Score compared to outputs of the same age (74th percentile)
  • Above-average Attention Score compared to outputs of the same age and source (63rd percentile)

Mentioned by

twitter
7 X users

Citations

dimensions_citation
88 Dimensions

Readers on

mendeley
125 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
Estimation of optic nerve sheath diameter on an initial brain computed tomography scan can contribute prognostic information in traumatic brain injury patients
Published in
Critical Care, March 2013
DOI 10.1186/cc12589
Pubmed ID
Authors

Aurélien Legrand, Patrick Jeanjean, Fanny Delanghe, Johann Peltier, Benoit Lecat, Hervé Dupont

Abstract

INTRODUCTION: The aim of this study was to evaluate the prognostic value of optic nerve sheath diameter (ONSD) measured on the initial brain computed tomography (CT) scan for intensive care unit (ICU) mortality in severe traumatic brain injury (TBI) patients. METHODS: A prospective observational study of all severe TBI patients admitted to a neurosurgical ICU (over a 10-month period). Demographic and clinical data and brain CT scan results were recorded. ONSD for each eye was measured on the initial CT scan. The group of ICU survivors was compared to non-survivors. Glasgow Outcome Scale (GOS) was evaluated six months after ICU discharge. RESULTS: Seventy-seven patients were included (age: 43 ± 18; 81% males; mean Injury Severity Score: 35 ± 15; ICU mortality: 28.5% (n = 22)). Mean ONSD on the initial brain CT scan was 7.8 ± 0.1 mm in non-survivors vs. 6.8 ± 0.1 mm in survivors (P < 0.001). The operative value of ONSD was a good predictor of mortality (area under the curve: 0.805). An ONSD cutoff ≥ 7.3 had a sensitivity of 86.4% and a specificity of 74.6% and was independently associated with mortality in this population (adjusted odds ratio 95% confidence interval: 22.7 (3.2 to 159.6), P = 0.002). There was a relationship between initial ONSD values and six-month GOS (P = 0.03). CONCLUSIONS: ONSD measured on the initial brain CT scan is independently associated with ICU mortality rate (when ≥ 7.3 mm) in severe TBI patients.

X Demographics

X Demographics

The data shown below were collected from the profiles of 7 X users who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 125 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Chile 1 <1%
France 1 <1%
Brazil 1 <1%
Czechia 1 <1%
Japan 1 <1%
United States 1 <1%
Unknown 119 95%

Demographic breakdown

Readers by professional status Count As %
Student > Master 17 14%
Researcher 16 13%
Other 15 12%
Student > Doctoral Student 13 10%
Student > Postgraduate 12 10%
Other 25 20%
Unknown 27 22%
Readers by discipline Count As %
Medicine and Dentistry 75 60%
Neuroscience 5 4%
Biochemistry, Genetics and Molecular Biology 4 3%
Agricultural and Biological Sciences 3 2%
Immunology and Microbiology 2 2%
Other 7 6%
Unknown 29 23%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 6. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 03 April 2013.
All research outputs
#6,714,791
of 25,373,627 outputs
Outputs from Critical Care
#3,786
of 6,554 outputs
Outputs of similar age
#53,565
of 210,264 outputs
Outputs of similar age from Critical Care
#61
of 169 outputs
Altmetric has tracked 25,373,627 research outputs across all sources so far. This one has received more attention than most of these and is in the 73rd percentile.
So far Altmetric has tracked 6,554 research outputs from this source. They typically receive a lot more attention than average, with a mean Attention Score of 20.8. This one is in the 42nd percentile – i.e., 42% of its peers scored the same or lower than it.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 210,264 tracked outputs that were published within six weeks on either side of this one in any source. This one has gotten more attention than average, scoring higher than 74% of its contemporaries.
We're also able to compare this research output to 169 others from the same source and published within six weeks on either side of this one. This one has gotten more attention than average, scoring higher than 63% of its contemporaries.