Evaluation of SD BIOLINE H. pylori Ag rapid test against double ELISA with SD H. pylori Ag ELISA and EZ-STEP H. pylori Ag ELISA tests

Overview of attention for article published in BMC Clinical Pathology, March 2018
Altmetric Badge

Citations

dimensions_citation
9 Dimensions

Readers on

mendeley
22 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
Evaluation of SD BIOLINE H. pylori Ag rapid test against double ELISA with SD H. pylori Ag ELISA and EZ-STEP H. pylori Ag ELISA tests
Published in
BMC Clinical Pathology, March 2018
DOI 10.1186/s12907-018-0071-6
Pubmed ID
Authors

Markos Negash, Afework Kassu, Bemnet Amare, Gizachew Yismaw, Beyene Moges

Abstract

Helicobacter pylori antibody titters fall very slowly even after successful treatment. Therefore, tests detecting H. pylori antibody lack specificity and sensitivity. On the other hand, H. pylori stool antigen tests are reported as an alternative assay because of their reliability and simplicity. However, the comparative performance of H. pylori stool antigen tests for detecting the presence of the bacterium in clinical specimens in the study area is not assessed. Therefore, in this study we evaluated the performance of SD BIOLINE H. pylori Ag rapid test with reference to the commercially available EZ- STEP ELISA and SD BIOLINE H. pylori Ag ELISA tests. Stool samples were collected to analyse the diagnostic performance of SD BIOLINE H. pylori Ag rapid test kit using SD H. pylori Ag ELISA kit and EZ- STEP ELISA tests as a gold standard. Serum samples were also collected from each patient to test for the presence of H. pylori antibodies using dBest H. pylori Test Disk. Sensitivity, specificity, predictive values and kappa value are assessed. P values < 0.05 were taken statistically significant. Stool and serum samples were collected from 201 dyspeptic patients and analysed. The sensitivity, specificity, positive and negative predictive values of the SD BIOLINE H. pylori Ag rapid test were: 95.6% (95% CI, 88.8-98.8), 92.5% (95%CI, 89-94.1%), 86.7% (95% CI, 80.5-89.6), and 97.6% (95% CI, 993.9-99.3) respectively. The performance of SD BIOLINE H. pylori Ag rapid test was better than the currently available antibody test in study area. Therefore, the SD BIOLINE Ag rapid stool test could replace and be used to diagnose active H. pylori infection before the commencement of therapy among dyspeptic patients.

Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 22 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 22 100%

Demographic breakdown

Readers by professional status Count As %
Lecturer 2 9%
Student > Bachelor 2 9%
Student > Master 2 9%
Student > Postgraduate 2 9%
Researcher 2 9%
Other 3 14%
Unknown 9 41%
Readers by discipline Count As %
Medicine and Dentistry 4 18%
Immunology and Microbiology 3 14%
Nursing and Health Professions 2 9%
Pharmacology, Toxicology and Pharmaceutical Science 2 9%
Biochemistry, Genetics and Molecular Biology 1 5%
Other 1 5%
Unknown 9 41%