↓ Skip to main content

Sonoporation efficacy on SiHa cells in vitro at raised bath temperatures—experimental validation of a prototype sonoporation device

Overview of attention for article published in Journal of Therapeutic Ultrasound, November 2015
Altmetric Badge

About this Attention Score

  • Average Attention Score compared to outputs of the same age

Mentioned by

twitter
1 X user

Citations

dimensions_citation
2 Dimensions

Readers on

mendeley
17 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
Sonoporation efficacy on SiHa cells in vitro at raised bath temperatures—experimental validation of a prototype sonoporation device
Published in
Journal of Therapeutic Ultrasound, November 2015
DOI 10.1186/s40349-015-0040-9
Pubmed ID
Authors

Jonathan Kivinen, Melissa Togtema, Gregor Mulzer, Joshua Choi, Ingeborg Zehbe, Laura Curiel, Samuel Pichardo

Abstract

A device was devised which aimed to reduce the time and expertise required to perform sonoporation on adherent cell cultures. This prototype device was used to examine the superficial effect of bath temperature on sonoporation efficacy. The prototype device consisted of six ultrasound transducers affixed beneath an Opticell stage. Six transducers with nominal diameters of 20 mm were constructed and the acoustic field of each was characterized using hydrophone scanning. A near field treatment plane was chosen for each transducer to minimize field heterogeneity in the near field. Cervical cancer-derived SiHa cells were exposed to nine different treatments in the presence of plasmid DNA-expressing green fluorescent protein (GFP). Ultrasound treatment with Definity ultrasound contrast agent (US+UCA) present, ultrasound treatment without contrast agent present (US), and a sham ultrasound treatment in the presence of ultrasound contrast agent (CA) were each performed at bath temperatures of 37, 39.5, and 42 °C. Each treatment was performed in biological triplicate. GFP expression and PARP expression following treatment were measured using fluorescent microscopy and digital image processing. Cell detachment was measured using phase contrast microscopy before and after treatment. Mean (± s.d.) transfection rates for the US+UCA treatment were 5.4(±0.92), 5.8(±1.3), and 5.3(±1.1) % at 37, 39.5, and 42 °C, respectively. GFP expression and cell detachment were both significantly affected by the presence of ultrasound contrast agent (p < 0.001, p < 0.001). Neither GFP expression, PARP expression, or detachment differed significantly between bath temperatures. Bath temperature did not impact the efficacy of sonoporation treatment on SiHa cells in vitro. The prototype device was found to be suitable for performing sonoporation on adherent cell cultures and will reduce the time and expertise required for conducting sonoporation experiments on adherent cell cultures in the future.

X Demographics

X Demographics

The data shown below were collected from the profile of 1 X user who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 17 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
United States 1 6%
Unknown 16 94%

Demographic breakdown

Readers by professional status Count As %
Student > Bachelor 4 24%
Researcher 4 24%
Professor 2 12%
Student > Master 2 12%
Student > Doctoral Student 1 6%
Other 1 6%
Unknown 3 18%
Readers by discipline Count As %
Biochemistry, Genetics and Molecular Biology 2 12%
Agricultural and Biological Sciences 2 12%
Physics and Astronomy 2 12%
Engineering 2 12%
Immunology and Microbiology 1 6%
Other 3 18%
Unknown 5 29%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 1. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 09 November 2015.
All research outputs
#15,349,796
of 22,832,057 outputs
Outputs from Journal of Therapeutic Ultrasound
#48
of 76 outputs
Outputs of similar age
#167,114
of 285,670 outputs
Outputs of similar age from Journal of Therapeutic Ultrasound
#3
of 3 outputs
Altmetric has tracked 22,832,057 research outputs across all sources so far. This one is in the 22nd percentile – i.e., 22% of other outputs scored the same or lower than it.
So far Altmetric has tracked 76 research outputs from this source. They typically receive a little more attention than average, with a mean Attention Score of 5.0. This one is in the 25th percentile – i.e., 25% of its peers scored the same or lower than it.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 285,670 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 32nd percentile – i.e., 32% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 3 others from the same source and published within six weeks on either side of this one.