↓ Skip to main content

A dose-volume histogram based decision-support system for dosimetric comparison of radiotherapy treatment plans

Overview of attention for article published in Radiation Oncology, December 2015
Altmetric Badge

About this Attention Score

  • Above-average Attention Score compared to outputs of the same age (52nd percentile)
  • High Attention Score compared to outputs of the same age and source (80th percentile)

Mentioned by

twitter
4 X users

Citations

dimensions_citation
37 Dimensions

Readers on

mendeley
96 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
A dose-volume histogram based decision-support system for dosimetric comparison of radiotherapy treatment plans
Published in
Radiation Oncology, December 2015
DOI 10.1186/s13014-015-0569-3
Pubmed ID
Authors

J. C. L. Alfonso, M. A. Herrero, L. Núñez

Abstract

The choice of any radiotherapy treatment plan is usually made after the evaluation of a few preliminary isodose distributions obtained from different beam configurations. Despite considerable advances in planning techniques, such final decision remains a challenging task that would greatly benefit from efficient and reliable assessment tools. For any dosimetric plan considered, data on dose-volume histograms supplied by treatment planning systems are used to provide estimates on planning target coverage as well as on sparing of organs at risk and the remaining healthy tissue. These partial metrics are then combined into a dose distribution index (DDI), which provides a unified, easy-to-read score for each competing radiotherapy plan. To assess the performance of the proposed scoring system, DDI figures for fifty brain cancer patients were retrospectively evaluated. Patients were divided in three groups depending on tumor location and malignancy. For each patient, three tentative plans were designed and recorded during planning, one of which was eventually selected for treatment. We thus were able to compare the plans with better DDI scores and those actually delivered. When planning target coverage and organs at risk sparing are considered as equally important, the tentative plan with the highest DDI score is shown to coincide with that actually delivered in 32 of the 50 patients considered. In 15 (respectively 3) of the remaining 18 cases, the plan with highest DDI value still coincides with that actually selected, provided that organs at risk sparing is given higher priority (respectively, lower priority) than target coverage. DDI provides a straightforward and non-subjective tool for dosimetric comparison of tentative radiotherapy plans. In particular, DDI readily quantifies differences among competing plans with similar-looking dose-volume histograms and can be easily implemented for any tumor type and localization, irrespective of the planning system and irradiation technique considered. Moreover, DDI permits to estimate the dosimetry impact of different priorities being assigned to sparing of organs at risk or to better target coverage.

X Demographics

X Demographics

The data shown below were collected from the profiles of 4 X users who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 96 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 96 100%

Demographic breakdown

Readers by professional status Count As %
Student > Ph. D. Student 18 19%
Student > Master 15 16%
Researcher 14 15%
Student > Bachelor 10 10%
Other 7 7%
Other 8 8%
Unknown 24 25%
Readers by discipline Count As %
Physics and Astronomy 28 29%
Medicine and Dentistry 14 15%
Nursing and Health Professions 7 7%
Engineering 4 4%
Mathematics 3 3%
Other 12 13%
Unknown 28 29%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 3. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 23 March 2016.
All research outputs
#13,218,410
of 22,836,570 outputs
Outputs from Radiation Oncology
#600
of 2,057 outputs
Outputs of similar age
#184,218
of 392,772 outputs
Outputs of similar age from Radiation Oncology
#11
of 57 outputs
Altmetric has tracked 22,836,570 research outputs across all sources so far. This one is in the 41st percentile – i.e., 41% of other outputs scored the same or lower than it.
So far Altmetric has tracked 2,057 research outputs from this source. They receive a mean Attention Score of 2.7. This one has gotten more attention than average, scoring higher than 69% of its peers.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 392,772 tracked outputs that were published within six weeks on either side of this one in any source. This one has gotten more attention than average, scoring higher than 52% of its contemporaries.
We're also able to compare this research output to 57 others from the same source and published within six weeks on either side of this one. This one has done well, scoring higher than 80% of its contemporaries.