Ex vivo testing of intact eye globes under inflation conditions to determine regional variation of mechanical stiffness

Overview of attention for article published in Eye and Vision, August 2016
Altmetric Badge

Citations

dimensions_citation
52 Dimensions

Readers on

mendeley
64 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
Ex vivo testing of intact eye globes under inflation conditions to determine regional variation of mechanical stiffness
Published in
Eye and Vision, August 2016
DOI 10.1186/s40662-016-0052-8
Pubmed ID
Authors

Charles Whitford, Akram Joda, Steve Jones, Fangjun Bao, Paolo Rama, Ahmed Elsheikh

Abstract

The eye globe exhibits significant regional variation of mechanical behaviour. The aim of this present study is to develop a new experimental technique for testing intact eye globes in a form that is representative of in vivo conditions, and therefore suitable for determining the material properties of the complete outer ocular tunic. A test rig has been developed to provide closed-loop control of either applied intra-ocular pressure or resulting apical displacement; measurement of displacements across the external surface of the eye globe using high-resolution digital cameras and digital image correlation software; prevention of rigid-body motion and protection of the ocular surface from environmental drying. The method has been demonstrated on one human and one porcine eye globe, which were cyclically loaded. Finite element models based on specimen specific tomography, free from rotational symmetry, were used along with experimental pressure-displacement data in an inverse analysis process to derive the mechanical properties of tissue in different regions of the eye's outer tunic. The test method enabled monitoring of mechanical response to intraocular pressure variation across the surface of the eye globe. For the two eyes tested, the method showed a gradual change in the sclera's stiffness from a maximum at the limbus to a minimum at the posterior pole, while in the cornea the stiffness was highest at the centre and lowest in the peripheral zone. Further, for both the sclera and cornea, the load-displacement behaviour did not vary significantly between loading cycles. The first methodology capable of mechanically testing intact eye globes, with applied loads and boundary conditions that closely represent in vivo conditions is introduced. The method enables determination of the regional variation in mechanical behaviour across the ocular surface.

Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 64 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
United Kingdom 1 2%
Spain 1 2%
Unknown 62 97%

Demographic breakdown

Readers by professional status Count As %
Student > Ph. D. Student 16 25%
Researcher 13 20%
Student > Master 10 16%
Other 3 5%
Student > Bachelor 2 3%
Other 6 9%
Unknown 14 22%
Readers by discipline Count As %
Engineering 30 47%
Medicine and Dentistry 7 11%
Agricultural and Biological Sciences 2 3%
Immunology and Microbiology 2 3%
Physics and Astronomy 2 3%
Other 5 8%
Unknown 16 25%