↓ Skip to main content

Open access to novel dual flow chamber technology for in vitro cell mechanotransduction, toxicity and pharamacokinetic studies

Overview of attention for article published in BioMedical Engineering OnLine, December 2007
Altmetric Badge

Citations

dimensions_citation
26 Dimensions

Readers on

mendeley
41 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
Open access to novel dual flow chamber technology for in vitro cell mechanotransduction, toxicity and pharamacokinetic studies
Published in
BioMedical Engineering OnLine, December 2007
DOI 10.1186/1475-925x-6-46
Pubmed ID
Authors

Eric J Anderson, Melissa L Knothe Tate

Abstract

A major stumbling block for researchers developing experimental models of mechanotransduction is the control of experimental variables, in particular the transmission of the mechanical forces at the cellular level. A previous evaluation of state of the art commercial perfusion chambers showed that flow regimes, applied to impart a defined mechanical stimulus to cells, are poorly controlled and that data from studies in which different chambers are utilized can not be compared, even if the target stress regimes are comparable. This study provides a novel chamber design to provide both physiologically-based flow regimes, improvements in control of experimental variables, as well as ease of use compared to commercial chambers. This novel design achieves controlled stresses through five gasket designs and both single- and dual-flow regimes. The imparted shear stress within the gasket geometry is well controlled. Fifty percent of the entire area of the 10 x 21 mm universal gasket (Gasket I, designed to impart constant magnitude shear stresses in the center of the chamber where outcome measures are taken), is exposed to target stresses. In the 8 mm diameter circular area at the center of the chamber (where outcome measures are made), over 92% of the area is exposed to the target stress (+/- 2.5%). In addition, other gasket geometries provide specific gradients of stress that vary with distance from the chamber inlet. Bench-top testing of the novel chamber prototype shows improvements, in the ease of use as well as in performance, compared to the other commercial chambers. The design of the chamber eliminates flow deviations due to leakage and bubbles and allows actual flow profiles to better conform with those predicted in computational models. The novel flow chamber design provides predictable and well defined mechanical forces at the surface of a cell monolayer, showing improvement over previously tested commercial chambers. The predictability of the imparted stress improves both experiment repeatability as well as the accuracy of inter-study comparisons. Carefully controlling the stresses on cells is critical in effectively mimicking in vivo situations. Overall, the improved perfusion flow chamber provides the needed resolution, standardization and in vitro model analogous to in vivo conditions to make the step towards greater use in research and the opportunity to enter the diagnostic and therapeutic market.

Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 41 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
United States 2 5%
Romania 1 2%
Unknown 38 93%

Demographic breakdown

Readers by professional status Count As %
Student > Ph. D. Student 13 32%
Researcher 8 20%
Student > Master 5 12%
Professor > Associate Professor 4 10%
Professor 3 7%
Other 5 12%
Unknown 3 7%
Readers by discipline Count As %
Engineering 12 29%
Agricultural and Biological Sciences 9 22%
Medicine and Dentistry 3 7%
Neuroscience 2 5%
Biochemistry, Genetics and Molecular Biology 2 5%
Other 10 24%
Unknown 3 7%