↓ Skip to main content

Dry-powder inhalers in patients with persistent airflow limitation: usability and preference

Overview of attention for article published in Multidisciplinary Respiratory Medicine, September 2016
Altmetric Badge

About this Attention Score

  • Average Attention Score compared to outputs of the same age
  • Average Attention Score compared to outputs of the same age and source

Mentioned by

policy
1 policy source

Citations

dimensions_citation
5 Dimensions

Readers on

mendeley
23 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
Dry-powder inhalers in patients with persistent airflow limitation: usability and preference
Published in
Multidisciplinary Respiratory Medicine, September 2016
DOI 10.1186/s40248-016-0068-x
Pubmed ID
Authors

Roberto W. Dal Negro, Massimiliano Povero

Abstract

Inhalation devices represent per sé critical factors because they can affect the therapeutic outcomes independently of the drug used. The role of patients' usability and preference (PUP) for Dry Powder Inhalers (DPIs) is high indeed because they can influence the extent of the adherence to treatment and the therapeutic outcomes. Aim of the study was to assess and compare the PUP of three different DPIs in out-patients with persistent airflow limitation due to asthma or COPD. The PUP of three different DPIs (Breezhaler; Genuair; Handihaler) were investigated by means of the Handling Questionnaire in out-patients with persistent airflow limitation needing an inhalation therapy. Patients had to report their preference before and after the nurse's instruction on the handling of each device. The nurse had also to note the critical steps during the patient's procedure for actuation; to count the number of attempts needed for actuating the device properly, and to measure the time (in sec.) required for these procedures. Data were collected up to three attempts per device. Welch test was used for normal distributed variables, while the Wilcoxon test for not normal distributed variables. The χ (2) test and the ANOVA test were also used. Univariate and multivariate regressions were also performed in order to investigate the effect of patients' characteristics and of technical differences of each device on their proper use. Three hundred thirty-three consecutive out-patients (age range 55-58 years, and well matched for gender), with persistent airway limitation of different severity were investigated, suffering from bronchial asthma (n = 175) or from chronic obstructive pulmonary disease (COPD) (n = 158). In particular, 127 patients (38 %) tested the three DPIs, while 110 (33 %) tested Breezhaler and Genuair, and 96 (29 %) Breezhaler and Handihaler. More than 50 % of patients who tested all devices preferred the Genuair and perceived this device as the easiest to use. The nurse's judgement confirmed their opinion. When compared to the other two DPIs, Genuair proved the least problematic either according to the patients' judgement and to the nurse's opinion. Mean number of attempts aimed to achieving the first proper actuation was lower with Genuair than with Breezhaler and Handihaler (1.5 vs 2.5-2.6, p < 0.0001). Finally, Genuair also proved the easiest to use and the least problematic according to the nurse judgement (0.0001), the most easily learned (0.0001), and that one with a successful rate of more than 56 % at the first attempt. Breezhaler and Handihaler needed an average of about one additional attempt to be used properly (p < 0.0001), and their usability proved significantly more difficult (OR of successful rate between 0.15 and 0.17, p < 0.001). In general, older patients needed more attempts to perform their first proper inhalation; their successful rate was lower, and they needed more time to learn how to use devices properly: with Genuair these differences were minimized. The possibility of grading objectively the performance of different DPIs in terms of their usability and therapeutic convenience in daily life represents a crucial operational opportunity to pursue. To note that a substantial discrepancy exists between the patients' belief "at glance" and the patients' effective usability with can be registered with some devices. From a general point of view, devices requiring less manual actions for their actuation confirmed their better usability and proper handling after less attempts. In particular, Genuair came out as the most preferred DPI also when several different aspects of preference and usability are assessed objectively and compared.

Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 23 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 23 100%

Demographic breakdown

Readers by professional status Count As %
Student > Master 5 22%
Other 4 17%
Student > Postgraduate 2 9%
Student > Ph. D. Student 2 9%
Researcher 2 9%
Other 2 9%
Unknown 6 26%
Readers by discipline Count As %
Medicine and Dentistry 5 22%
Agricultural and Biological Sciences 3 13%
Nursing and Health Professions 3 13%
Pharmacology, Toxicology and Pharmaceutical Science 2 9%
Arts and Humanities 1 4%
Other 2 9%
Unknown 7 30%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 3. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 22 January 2021.
All research outputs
#8,534,528
of 25,371,288 outputs
Outputs from Multidisciplinary Respiratory Medicine
#124
of 307 outputs
Outputs of similar age
#124,520
of 346,160 outputs
Outputs of similar age from Multidisciplinary Respiratory Medicine
#3
of 6 outputs
Altmetric has tracked 25,371,288 research outputs across all sources so far. This one is in the 43rd percentile – i.e., 43% of other outputs scored the same or lower than it.
So far Altmetric has tracked 307 research outputs from this source. They typically receive a lot more attention than average, with a mean Attention Score of 11.3. This one has gotten more attention than average, scoring higher than 54% of its peers.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 346,160 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 48th percentile – i.e., 48% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 6 others from the same source and published within six weeks on either side of this one. This one has scored higher than 3 of them.