↓ Skip to main content

Pulse pressure variation shows a direct linear correlation with tidal volume in anesthetized healthy patients

Overview of attention for article published in BMC Anesthesiology, September 2016
Altmetric Badge

Mentioned by

twitter
1 X user
facebook
1 Facebook page

Citations

dimensions_citation
12 Dimensions

Readers on

mendeley
51 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
Pulse pressure variation shows a direct linear correlation with tidal volume in anesthetized healthy patients
Published in
BMC Anesthesiology, September 2016
DOI 10.1186/s12871-016-0233-y
Pubmed ID
Authors

Yi Liu, Jing-sheng Lou, Wei-dong Mi, Wei-xiu Yuan, Qiang Fu, Min Wang, Jing Qu

Abstract

The settings of mechanical ventilation, like tidal volume (VT), occasionally need to be adjusted in the process of anesthesia for some special reasons. The aim of this study was therefore to assess the relationship between pulse pressure variations (PPVs) in different settings of VT in anesthetized healthy patients under mechanical ventilation. Sixty nine ASA I-II patients scheduled for gastrointestinal surgery under general anesthesia were included in this prospective study. All the patients were ventilated at a VT of 6, 8 or 10 ml/kg (predicted body weight) with no positive end expiratory pressure (PEEP) in a random order after intubation. PPV, mean arterial blood pressure, and other hemodynamic and respiratory parameters were recorded in each VT setting respectively after Partial Pressure of End-Tidal Expiration Carbon Dioxide (PetCO2) maintained between 30 mmHg and 40 mmHg by changing Respiratory Rate (RR) before incision. The values of PPV at different settings of VT showed a tight correlation between each other (6 vs. 8 ml/kg: r = 0.97, P < 0.0001; 6 vs.10 ml/kg: r = 0.95, P < 0.0001; 8 vs. 10 ml/kg: r = 0.98, P < 0.0001, respectively). There is a direct linear correlation between PPVs at different tidal volumes in anesthetized ASA I-II patients. PPV in any of the 3 VT settings (6, 8 or 10 ml/kg) can deduce that in any other 2 settings. Further studies are needed to explore the effect of intraoperative confounders for this knowledge to be clinically applied. NCT01950949 , www.clinicaltrials.gov , July 26, 2013.

X Demographics

X Demographics

The data shown below were collected from the profile of 1 X user who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 51 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 51 100%

Demographic breakdown

Readers by professional status Count As %
Other 9 18%
Researcher 7 14%
Student > Postgraduate 7 14%
Professor > Associate Professor 4 8%
Student > Master 4 8%
Other 6 12%
Unknown 14 27%
Readers by discipline Count As %
Medicine and Dentistry 27 53%
Nursing and Health Professions 3 6%
Unspecified 2 4%
Mathematics 1 2%
Veterinary Science and Veterinary Medicine 1 2%
Other 4 8%
Unknown 13 25%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 1. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 09 September 2016.
All research outputs
#18,469,995
of 22,886,568 outputs
Outputs from BMC Anesthesiology
#994
of 1,502 outputs
Outputs of similar age
#253,897
of 332,538 outputs
Outputs of similar age from BMC Anesthesiology
#24
of 35 outputs
Altmetric has tracked 22,886,568 research outputs across all sources so far. This one is in the 11th percentile – i.e., 11% of other outputs scored the same or lower than it.
So far Altmetric has tracked 1,502 research outputs from this source. They receive a mean Attention Score of 3.1. This one is in the 21st percentile – i.e., 21% of its peers scored the same or lower than it.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 332,538 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 12th percentile – i.e., 12% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 35 others from the same source and published within six weeks on either side of this one. This one is in the 20th percentile – i.e., 20% of its contemporaries scored the same or lower than it.