Title |
Single-source chest-abdomen-pelvis cancer staging on a third generation dual-source CT system: comparison of automated tube potential selection to second generation dual-source CT
|
---|---|
Published in |
Cancer Imaging, October 2016
|
DOI | 10.1186/s40644-016-0093-1 |
Pubmed ID | |
Authors |
Clara Park, Tatjana Gruber-Rouh, Doris Leithner, Amelie Zierden, Mortiz H. Albrecht, Julian L. Wichmann, Boris Bodelle, Mohamed Elsabaie, Jan-Erik Scholtz, Moritz Kaup, Thomas J. Vogl, Martin Beeres |
Abstract |
Evaluation of latest generation automated attenuation-based tube potential selection (ATPS) impact on image quality and radiation dose in contrast-enhanced chest-abdomen-pelvis computed tomography examinations for gynaecologic cancer staging. This IRB approved single-centre, observer-blinded retrospective study with a waiver for informed consent included a total of 100 patients with contrast-enhanced chest-abdomen-pelvis CT for gynaecologic cancer staging. All patients were examined with activated ATPS for adaption of tube voltage to body habitus. 50 patients were scanned on a third-generation dual-source CT (DSCT), and another 50 patients on a second-generation DSCT. Predefined image quality setting remained stable between both groups at 120 kV and a current of 210 Reference mAs. Subjective image quality assessment was performed by two blinded readers independently. Attenuation and image noise were measured in several anatomic structures. Signal-to-noise ratio (SNR) was calculated. For the evaluation of radiation exposure, CT dose index (CTDIvol) values were compared. Diagnostic image quality was obtained in all patients. The median CTDIvol (6.1 mGy, range 3.9-22 mGy) was 40 % lower when using the algorithm compared with the previous ATCM protocol (median 10.2 mGy · cm, range 5.8-22.8 mGy). A reduction in potential to 90 kV occurred in 19 cases, a reduction to 100 kV in 23 patients and a reduction to 110 kV in 3 patients of our experimental cohort. These patients received significantly lower radiation exposure compared to the former used protocol. Latest generation automated ATPS on third-generation DSCT provides good diagnostic image quality in chest-abdomen-pelvis CT while average radiation dose is reduced by 40 % compared to former ATPS protocol on second-generation DSCT. |
Mendeley readers
Geographical breakdown
Country | Count | As % |
---|---|---|
Unknown | 30 | 100% |
Demographic breakdown
Readers by professional status | Count | As % |
---|---|---|
Student > Bachelor | 5 | 17% |
Researcher | 5 | 17% |
Student > Master | 4 | 13% |
Other | 2 | 7% |
Unspecified | 2 | 7% |
Other | 3 | 10% |
Unknown | 9 | 30% |
Readers by discipline | Count | As % |
---|---|---|
Medicine and Dentistry | 7 | 23% |
Nursing and Health Professions | 5 | 17% |
Unspecified | 2 | 7% |
Social Sciences | 2 | 7% |
Psychology | 1 | 3% |
Other | 2 | 7% |
Unknown | 11 | 37% |