Title
Measurement of HbA1c in multicentre diabetes trials – should blood samples be tested locally or sent to a central laboratory: an agreement analysis
Published in
Trials, October 2016
DOI 10.1186/s13063-016-1640-6
Pubmed ID
Authors

Barbara N. Arch, Joanne Blair, Andrew McKay, John W. Gregory, Paul Newland, Carrol Gamble

Abstract

Glycated haemoglobin (HbA1c) is an important outcome measure in diabetes clinical trials. For multicentre designs, HbA1c can be measured locally at participating centres or by sending blood samples to a central laboratory. This study analyses the agreement between local and central measurements, using 1-year follow-up data collected in a multicentre randomised controlled trial (RCT) of newly diagnosed children with type I diabetes. HbA1c measurements were routinely analysed both locally and centrally at baseline and then at 3, 6, 9 and 12 months and the data reported in mmol/mol. Agreement was assessed by calculating the bias and 95 % limits of agreement, using the Bland-Altman analysis method. A predetermined benchmark for clinically acceptable margin of error between measurements was subjectively set as ±10 % for HbA1c. The percentage of pairs of measurements that were classified as clinically acceptable was calculated. Descriptive statistics were used to examine the agreement within centres. Treatment group was not considered. Five hundred and ninety pairs of measurement, representing 255 children and 15 trial centres across four follow-up time points, were compared. There was no significant bias: local measurements were an average of 0.16 mmol/mol (SD = 4.5, 95 % CI -0.2 to 0.5) higher than central. The 95 % limits of agreement were -8.6 to 9.0 mmol/mol (local minus central). Eighty percent of local measurements were within ±10 % of corresponding central measurements. Some trial centres were more varied in the differences observed between local and central measurements: IQRs ranging from 3 to 9 mmol/mol; none indicated systematic bias. Variation in agreement between HbA1c measurements was greater than had been expected although no overall bias was detected and standard deviations were similar. Discrepancies were present across all participating centres. These findings have implications for the comparison of standards of clinical care between centres, the design of future multicentre RCTs and existing quality assurance processes for HbA1c measurements. We recommend that centralised HbA1c measurement is preferable in the multicentre clinical trial setting. Eudract No. 2010-023792-25 , registered on 4 November 2010.

X Demographics

X Demographics

The data shown below were collected from the profiles of 2 X users who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 52 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 52 100%

Demographic breakdown

Readers by professional status Count As %
Student > Master 10 19%
Student > Bachelor 8 15%
Student > Ph. D. Student 4 8%
Other 3 6%
Lecturer 2 4%
Other 7 13%
Unknown 18 35%
Readers by discipline Count As %
Medicine and Dentistry 16 31%
Nursing and Health Professions 7 13%
Biochemistry, Genetics and Molecular Biology 2 4%
Pharmacology, Toxicology and Pharmaceutical Science 2 4%
Business, Management and Accounting 1 2%
Other 5 10%
Unknown 19 37%