Disinfection of incubators in neonatal intensive care units: impact of steam pulverization on bacterial colonization

Overview of attention for article published in Antimicrobial Resistance & Infection Control, March 2023
Altmetric Badge

About this Attention Score

  • In the top 25% of all research outputs scored by Altmetric
  • Good Attention Score compared to outputs of the same age (76th percentile)
  • Good Attention Score compared to outputs of the same age and source (79th percentile)

Mentioned by

twitter
7 X users
wikipedia
1 Wikipedia page

Readers on

mendeley
8 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
Disinfection of incubators in neonatal intensive care units: impact of steam pulverization on bacterial colonization
Published in
Antimicrobial Resistance & Infection Control, March 2023
DOI 10.1186/s13756-023-01226-y
Pubmed ID
Authors

Marion Reboux, Marie Chavignon, Anne Tristan, Franck Plaisant, Frédéric Laurent, Marine Butin

Abstract

In neonatal intensive care units (NICUs), neonates requiring medical care after birth, including very vulnerable preterm infants, are housed in incubators. Previous studies have reported that the standard chemical disinfection measures used to disinfect these incubators are insufficient to eradicate contaminating bacteria, leading to a worrying infectious risk for preterm neonates. This study aimed to evaluate the efficacy of a disinfection method based on steam pulverization to eradicate the persistent bacterial contamination in such incubators. In a tertiary NICU, 20 incubators were monitored qualitatively for bacterial contamination at five different sites (the rubber grommet, the left door handles, the temperature adjustment button, the mattress and the scale) using a culture method at three times: before and after steam pulverization then 24 h after turning on and housing a new neonate. Clinical data of neonates housed in each incubator were retrieved from the medical records to identify potential occurrence of late onset sepsis (LOS). Just after steam pulverization, only two incubators were free from bacteria. Before disinfection 87% of all the samples were contaminated compared to 61% after disinfection. After 24 h, the proportion of contaminated samples reached 85%. Mattresses and scales were the most frequently contaminated incubator sites with respectively 90% and 80% positive samples after disinfection compared to 100% and 90% before disinfection. Coagulase-negative staphylococci, Enterococcus, Enterobacteria and Bacillus resisted disinfection and were identified on respectively 90%, 20%, 5% and 45% of incubators just after disinfection. Three preterm neonates developed LOS after being housed in a disinfected incubator but the bacterial species involved have not been identified in their incubator after disinfection. In two cases, the bacterium had been isolated from the mattress 24 h after housing the infected patient. Steam pulverization is not sufficient to eradicate bacterial contamination of incubators. These results highlight the urgent need for an effective disinfection method, especially for mattresses that are in constant contact with patients. In parallel, new incubator designs and mattress protections must be developed.

X Demographics

X Demographics

The data shown below were collected from the profiles of 7 X users who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 8 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 8 100%

Demographic breakdown

Readers by professional status Count As %
Unspecified 2 25%
Professor > Associate Professor 1 13%
Other 1 13%
Unknown 4 50%
Readers by discipline Count As %
Unspecified 2 25%
Medicine and Dentistry 2 25%
Unknown 4 50%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 7. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 21 November 2023.
All research outputs
#5,223,712
of 25,528,120 outputs
Outputs from Antimicrobial Resistance & Infection Control
#559
of 1,466 outputs
Outputs of similar age
#101,063
of 428,082 outputs
Outputs of similar age from Antimicrobial Resistance & Infection Control
#9
of 39 outputs
Altmetric has tracked 25,528,120 research outputs across all sources so far. Compared to these this one has done well and is in the 79th percentile: it's in the top 25% of all research outputs ever tracked by Altmetric.
So far Altmetric has tracked 1,466 research outputs from this source. They typically receive a lot more attention than average, with a mean Attention Score of 15.3. This one has gotten more attention than average, scoring higher than 61% of its peers.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 428,082 tracked outputs that were published within six weeks on either side of this one in any source. This one has done well, scoring higher than 76% of its contemporaries.
We're also able to compare this research output to 39 others from the same source and published within six weeks on either side of this one. This one has done well, scoring higher than 79% of its contemporaries.