↓ Skip to main content

Individualized flow-controlled versus conventional pressure-controlled ventilation in on-pump heart surgery (FLOWVENTIN HEARTSURG): study protocol for a randomized controlled trial

Overview of attention for article published in Trials, March 2023
Altmetric Badge

Mentioned by

twitter
2 X users

Readers on

mendeley
10 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
Individualized flow-controlled versus conventional pressure-controlled ventilation in on-pump heart surgery (FLOWVENTIN HEARTSURG): study protocol for a randomized controlled trial
Published in
Trials, March 2023
DOI 10.1186/s13063-023-07201-7
Pubmed ID
Authors

Simon Becker, Romina Schnitzler, Martin Rembecki, Johannes Geppert, Christian T. Kurz, Lisa-Marie Wichelhaus, Nina Timmesfeld, Peter K. Zahn

Abstract

In on-pump cardiac surgery, lungs are at high risk of periprocedural organ impairment because of atelectasis formation, ventilator-induced lung injury, and hyperinflammation due to the cardiopulmonary bypass which results in postoperative pulmonary complications in half of this patient population. The new ventilation mode flow-controlled ventilation (FCV) uniquely allows full control of ins- and expiratory airway flows. This approach reduces the mechanical power of invasive ventilation as a possible cause of ventilator-induced lung injury. The scope of FLOWVENTIN HEARTSURG is to compare perioperative individualized FCV with best clinical practice pressure-controlled ventilation (PVC) modes in patients with elective on-pump cardiac surgery procedures. We hypothesize that the postoperative inflammatory response can be reduced by the perioperative application of FCV compared to PCV. FLOWVENTIN HEARTSURG is a single-center, randomized, parallel-group trial with two intervention arms: perioperative PCV modes (n = 70, PCV group) with an individualized positive end-expiratory pressure (PEEP) and a tidal volume of 6-8 ml/kg predicted bodyweight compared to perioperative FCV (n = 70, FCV group) with an individualized PEEP and driving pressure, resulting in a liberal tidal volume. As the primary study endpoint interleukin 8 plasma level is assessed 6 h after cardiopulmonary bypass as a surrogate biomarker of systemic and pulmonary inflammation. As secondary aims clinically relevant patient outcomes are analyzed, e.g., perioperative lung function regarding oxygenation indices, postoperative pulmonary and extra-pulmonary complications, SIRS-free days as well as ICU and total inpatient stays. As additional sub-studies with an exploratory approach perioperative right ventricular function parameters are assessed by echocardiography and perioperative lung aeration by electrical impedance tomography. Current paradigms regarding protective low tidal volume ventilation are consciously left in the FCV intervention group in order to reduce mechanical power as a determinant of ventilator-induced lung injury in this high-risk patient population and procedures. This approach will be compared in a randomized controlled trial with current best clinical practice PCV in FLOWVENTIN HEARTSURG. German Clinical Trials Register DRKS00018956 . Registered on 12 June 2020 (Version 1), last update on 22 August 2022 (Version 4).

X Demographics

X Demographics

The data shown below were collected from the profiles of 2 X users who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 10 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 10 100%

Demographic breakdown

Readers by professional status Count As %
Unspecified 1 10%
Librarian 1 10%
Professor > Associate Professor 1 10%
Researcher 1 10%
Unknown 6 60%
Readers by discipline Count As %
Medicine and Dentistry 3 30%
Unspecified 1 10%
Arts and Humanities 1 10%
Unknown 5 50%