↓ Skip to main content

Novel intramedullary device for lengthening transfemoral residual limbs

Overview of attention for article published in Journal of Orthopaedic Surgery and Research, March 2017
Altmetric Badge

Mentioned by

twitter
1 X user

Citations

dimensions_citation
5 Dimensions

Readers on

mendeley
50 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
Novel intramedullary device for lengthening transfemoral residual limbs
Published in
Journal of Orthopaedic Surgery and Research, March 2017
DOI 10.1186/s13018-017-0553-8
Pubmed ID
Authors

Todd A. Kuiken, Bennet A. Butler, Tom Sharkey, Andre D. Ivy, Daniel Li, Terrance D. Peabody

Abstract

Lower limb loss is a highly disabling medical condition that can severely impact a person's quality of life. Recovery becomes especially challenging if an amputee has a short residual limb, which can complicate proper prosthetic fitting, causing discomfort, difficulties in suspension, and reduced mobility. Current limb lengthening techniques such as the Ilizarov apparatus and external fixators are cumbersome, uncomfortable, and have high complication rates. In this study, we investigated the effectiveness of a novel limb-lengthening device that uses intramedullary bone lengthening and requires only one percutaneous rod at the end of the limb during the distraction phase. Only the intramedullary nail remains after the distraction phase, and no external components are required during the consolidation phase. We hypothesize that this system would create a much easier experience for the patient. The system was first tested in a mock surgical implantation using plastic femur bones. The device was then tested in a series of cadaveric experiments using pelvis-to-knee specimens by a group of surgeons. Surgeons evaluated the surgical insertion technique, soft tissue considerations, hardware fixation strategies, and the effectiveness of the distraction mechanism. Revisions and improvements to the device and surgical procedure were made based on the results from the cadaveric experiments. A questionnaire was given to two visiting surgeons following the final iteration of the device. The surgeons reported that the system effectively lengthened the limb, was sturdy, and could be installed efficiently. However, there remains a risk of infection and soft tissue imbalances, similar to that introduced by an external fixator device. Suggestions on how to improve the design of the device and mitigate infection through postoperative management and surgical standard of care will be considered for future clinical trials. The described intramedullary residual limb-lengthening device has evolved from a prototype to a mature model tested in six cadaveric experiments to date. Further mechanical and functional testing is needed to finalize the device before testing in patients.

X Demographics

X Demographics

The data shown below were collected from the profile of 1 X user who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 50 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 50 100%

Demographic breakdown

Readers by professional status Count As %
Researcher 9 18%
Student > Bachelor 7 14%
Student > Master 5 10%
Student > Postgraduate 4 8%
Student > Doctoral Student 3 6%
Other 8 16%
Unknown 14 28%
Readers by discipline Count As %
Medicine and Dentistry 22 44%
Nursing and Health Professions 6 12%
Engineering 3 6%
Psychology 1 2%
Physics and Astronomy 1 2%
Other 1 2%
Unknown 16 32%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 1. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 31 March 2017.
All research outputs
#18,540,642
of 22,962,258 outputs
Outputs from Journal of Orthopaedic Surgery and Research
#962
of 1,394 outputs
Outputs of similar age
#235,341
of 309,402 outputs
Outputs of similar age from Journal of Orthopaedic Surgery and Research
#24
of 43 outputs
Altmetric has tracked 22,962,258 research outputs across all sources so far. This one is in the 11th percentile – i.e., 11% of other outputs scored the same or lower than it.
So far Altmetric has tracked 1,394 research outputs from this source. They receive a mean Attention Score of 3.6. This one is in the 15th percentile – i.e., 15% of its peers scored the same or lower than it.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 309,402 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 12th percentile – i.e., 12% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 43 others from the same source and published within six weeks on either side of this one. This one is in the 2nd percentile – i.e., 2% of its contemporaries scored the same or lower than it.