↓ Skip to main content

Rapid simultaneous determination of indacaterol maleate and glycopyrronium bromide in inhaler capsules using a validated stability-indicating monolithic LC method

Overview of attention for article published in BMC Chemistry, May 2017
Altmetric Badge

Mentioned by

twitter
2 X users

Citations

dimensions_citation
10 Dimensions

Readers on

mendeley
27 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
Rapid simultaneous determination of indacaterol maleate and glycopyrronium bromide in inhaler capsules using a validated stability-indicating monolithic LC method
Published in
BMC Chemistry, May 2017
DOI 10.1186/s13065-017-0264-6
Pubmed ID
Authors

Sahar Zayed, Fathalla Belal

Abstract

Chronic obstructive pulmonary disease (COPD) is a major cause of morbidity and mortality worldwide. A combination of indacaterol maleate with glycopyrronium bromide has recently been approved as a once-daily maintenance therapy in patients with COPD. The very low dose (μg level/capsule) renders the analysis of such products challenges. This study reports for the first time about HPLC method for the quality control of such combination and it is a stability indicating at the same time. A rapid, simple, precise and reproducible HPLC method was developed and validated for simultaneous determination of indacaterol maleate and glycopyrronium bromide using tenoxicam as an internal standard. The chromatographic separation was achieved on an onyx monolithic C18 column (100 × 4.6 mm) using a mobile phase consisting of acetonitrile and 30 mM phosphate buffer (pH 3.5) (30:70, v/v), run at a flow rate of 2 mL/min with UV detection at 210 nm. The total analysis time was less than 3 min. The HPLC method was validated for linearity, limits of detection and quantitation, precision, accuracy, system suitability and robustness. Calibration curves were obtained in the concentration ranges of 1-44 µg/mL for indacaterol maleate and 0.5-20 µg/mL for glycopyrronium bromide. Stability tests were done through exposure of the analyte solution for different stress conditions and the results indicate no interference of degradants with HPLC method. The method was successfully applied for the quantitative analysis of indacaterol maleate and glycopyrronium bromide both individually and in a combined pharmaceutical inhaler capsules to support the quality control and to assure the therapeutic efficacy of the two drugs. The simple procedure involved in sample preparation and the short run-time added the important property of high throughput to the method. Graphical abstract Chemical structures and representative HPLC chromatogram of indacaterol maleate (IND; 22 μg/mL), glycopyrronium bromide (GLY; 10 μg/mL) and tenoxicam (IS, 15μg/mL) in commercial capsules.

X Demographics

X Demographics

The data shown below were collected from the profiles of 2 X users who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 27 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 27 100%

Demographic breakdown

Readers by professional status Count As %
Student > Master 6 22%
Student > Ph. D. Student 3 11%
Professor 2 7%
Other 1 4%
Lecturer 1 4%
Other 2 7%
Unknown 12 44%
Readers by discipline Count As %
Chemistry 5 19%
Pharmacology, Toxicology and Pharmaceutical Science 4 15%
Medicine and Dentistry 2 7%
Nursing and Health Professions 1 4%
Engineering 1 4%
Other 0 0%
Unknown 14 52%