↓ Skip to main content

“Reliability of the Norwegian version of the short physical performance battery in older people with and without dementia”

Overview of attention for article published in BMC Geriatrics, June 2017
Altmetric Badge

Mentioned by

twitter
1 X user

Citations

dimensions_citation
66 Dimensions

Readers on

mendeley
209 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
“Reliability of the Norwegian version of the short physical performance battery in older people with and without dementia”
Published in
BMC Geriatrics, June 2017
DOI 10.1186/s12877-017-0514-4
Pubmed ID
Authors

Cecilie Fromholt Olsen, Astrid Bergland

Abstract

The purpose of the study was to establish the test-retest reliability of the Norwegian version of the Short Physical Performance Battery (SPPB). This was a cross- sectional reliability study. A convenience sample of 61 older adults with a mean age of 88.4(8.1) was tested by two different physiotherapists at two time points. The mean time interval between tests was 2.5 days. The Intraclass Correlation Coefficient model 3.1 (ICC, 3.1) with 95% confidence intervals as well as the weighted Kappa (K) were used as measures of relative reliability. The Standard Error of Measurement (SEM) and Minimal Detectable Change (MDC) were used to measure absolute reliability. The results were also analyzed for a subgroup of 24 older people with dementia. The ICC reflected high relative reliability for the SPPB summary score and the 4 m walk test (4mwt), both for the total sample (ICC = 0.92, and 0.91 respectively)) and for the subgroup with dementia (ICC = 0.84 and 0.90 respectively). Furthermore, weighted Ks for the SPPB subscales were 0.64 for the chair stand, 0.80 for gait and 0.52 for balance for the total sample and almost identical for the subgroup with dementia. MDC-values at the 95% confidence intervals (MDC95) were calculated at 0.8 for the total score of SPPB and 0.39 m/s for the 4mwt in the total sample. For the subgroup with dementia MDC95 was 1.88 for the total score of SPPB and 0.28 m/s for 4mwt. The SPPB total score and the timed walking test showed overall high relative and absolute reliability for the total sample indicating that the Norwegian version of the SPPB is reliable when used by trained physiotherapists with older people. The reliability of the Norwegian SPPB in older people with dementia seems high, but due to a small sample size this needs further investigation.

X Demographics

X Demographics

The data shown below were collected from the profile of 1 X user who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 209 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 209 100%

Demographic breakdown

Readers by professional status Count As %
Student > Master 43 21%
Student > Bachelor 22 11%
Student > Ph. D. Student 17 8%
Researcher 12 6%
Student > Doctoral Student 11 5%
Other 26 12%
Unknown 78 37%
Readers by discipline Count As %
Nursing and Health Professions 47 22%
Medicine and Dentistry 25 12%
Sports and Recreations 13 6%
Computer Science 6 3%
Psychology 6 3%
Other 21 10%
Unknown 91 44%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 1. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 29 June 2017.
All research outputs
#20,429,992
of 22,982,639 outputs
Outputs from BMC Geriatrics
#2,888
of 3,223 outputs
Outputs of similar age
#275,828
of 317,140 outputs
Outputs of similar age from BMC Geriatrics
#48
of 51 outputs
Altmetric has tracked 22,982,639 research outputs across all sources so far. This one is in the 1st percentile – i.e., 1% of other outputs scored the same or lower than it.
So far Altmetric has tracked 3,223 research outputs from this source. They typically receive more attention than average, with a mean Attention Score of 9.5. This one is in the 1st percentile – i.e., 1% of its peers scored the same or lower than it.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 317,140 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 1st percentile – i.e., 1% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 51 others from the same source and published within six weeks on either side of this one. This one is in the 1st percentile – i.e., 1% of its contemporaries scored the same or lower than it.