↓ Skip to main content

A novel needle for subcutaneous injection of interferon beta-1a: effect on pain in volunteers and satisfaction in patients with multiple sclerosis

Overview of attention for article published in BMC Neurology, October 2008
Altmetric Badge

Readers on

mendeley
47 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
A novel needle for subcutaneous injection of interferon beta-1a: effect on pain in volunteers and satisfaction in patients with multiple sclerosis
Published in
BMC Neurology, October 2008
DOI 10.1186/1471-2377-8-38
Pubmed ID
Authors

Amer Jaber, Gian B Bozzato, Lionel Vedrine, Wes A Prais, Julie Berube, Philippe E Laurent

Abstract

To reduce injection pain and improve satisfaction, a thinner (29-gauge [29G]), sharper (5-bevel) needle than the 27G/3-bevel needle used previously to inject interferon (IFN) beta-1a, 44 or 22 mcg subcutaneously (sc) three times weekly (tiw), was developed for use in multiple sclerosis (MS). Two clinical trials in healthy volunteers and five surveys of patients with MS were conducted to assess whether the 29G/5-bevel needle with a Thermo Plastic Elastomer (TPE) needle shield (a sleeve that houses the tip of the needle in a secure location) is an improvement over the 27G/3-bevel needle with a rubber shield for injection of IFN beta-1a, 44 or 22 mcg sc tiw. Parameters assessed were: pain and ease of insertion (healthy volunteer and nurse responses on subjective pain measurement scales); and patient satisfaction (surveys of patients with MS). In healthy volunteers, the 29G/5-bevel needle with TPE shield was associated with the least perceived pain on the Visual Analog Scale (VAS) and Verbal VAS (VB-VAS); mean VAS pain scores decreased by 40% and skin penetration improved by 69% compared with the 27G/3-bevel needle with standard rubber shield (p < 0.01). Pooled results from surveys of patients with MS indicated that 63% of patients thought that injections were less painful with the 29G/5-bevel needle than the 27G/3-bevel needle. Results from individual surveys indicated that the 29G/5-bevel needle was an improvement over the 27G/3-bevel needle for ease of insertion, injection-site reactions, bruising, burning and stinging. Together these studies indicate that the 29G/5-bevel needle with the TPE shield is an improvement over the 27G/3-bevel needle with standard rubber shield in terms of pain, ease of insertion and patient satisfaction. These improvements are expected to result in improved compliance in patients with MS treated with IFN beta-1a, 44 or 22 mcg sc tiw.

Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 47 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 47 100%

Demographic breakdown

Readers by professional status Count As %
Researcher 11 23%
Student > Ph. D. Student 4 9%
Student > Master 3 6%
Other 3 6%
Student > Doctoral Student 2 4%
Other 8 17%
Unknown 16 34%
Readers by discipline Count As %
Medicine and Dentistry 9 19%
Psychology 3 6%
Pharmacology, Toxicology and Pharmaceutical Science 3 6%
Nursing and Health Professions 2 4%
Agricultural and Biological Sciences 2 4%
Other 12 26%
Unknown 16 34%