↓ Skip to main content

An assessment of outcomes with intramedullary fixation of fractured ribs

Overview of attention for article published in Journal of Cardiothoracic Surgery, August 2016
Altmetric Badge

Citations

dimensions_citation
19 Dimensions

Readers on

mendeley
27 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
An assessment of outcomes with intramedullary fixation of fractured ribs
Published in
Journal of Cardiothoracic Surgery, August 2016
DOI 10.1186/s13019-016-0510-3
Pubmed ID
Authors

Silvana Marasco, Margaret Quayle, Robyn Summerhayes, Ilija D. Šutalo, Petar Liovic

Abstract

Surgical management of fractured ribs with internal fixation is an increasingly accepted therapy. Concurrently, specific rib fixation prostheses are being developed which should improve results and minimise hardware and rib/splint construct failures. The Synthes titanium intramedullary splint lends itself to difficult to access areas such as posterior rib fractures and fractures under the scapula. We analyse a case series of patients in whom this rib fixation prosthesis has been used. Fifteen patients received 35 intramedullary splints. Follow up at 3 and 6 months was performed with three dimensional computed tomography scanning to assess for bone alignment, callus formation and healing, residual deformity, hardware failure or cut through. Computerized finite element analysis (FEA) was used to model forces acting on a posterior fracture with and without an intramedullary fixation splint in situ. Complete healing (bony union) was noted in only 3 (9 %) of the fractures fixed with splints by 3 months. Partial healing (cartilaginous union) was noted in 28 of the 33 fractures (85 %), and non healing was noted in only 2 (6 %). In both those two patients, failure at the rib / splint interface was noted after both patients reported sneezing. No hardware failures were noted. By 6 months the fractures which had shown partial healing, had all completely healed. There were no late failures (between 3 and 6 months) of either hardware or rib/splint interfaces. FEA modelling identified sites of increased stress in the rib at the rib / splint interface and in a modelled intramedullary splint where it spans the fracture. Further analysis of outcomes with intramedullary splints is warranted as well as further development of intramedullary rib fixation solutions.

Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 27 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 27 100%

Demographic breakdown

Readers by professional status Count As %
Student > Doctoral Student 4 15%
Researcher 3 11%
Professor > Associate Professor 3 11%
Student > Bachelor 2 7%
Student > Postgraduate 2 7%
Other 6 22%
Unknown 7 26%
Readers by discipline Count As %
Medicine and Dentistry 15 56%
Unspecified 1 4%
Nursing and Health Professions 1 4%
Engineering 1 4%
Unknown 9 33%