Title
An inappropriate pacing threshold increase after repeated electrical storm in a patient with implantable cardioverter defibrillator
Published in
BMC Cardiovascular Disorders, October 2017
DOI 10.1186/s12872-017-0695-y
Pubmed ID
Authors

Ye Zhu, Xiang Gu, Chao Xu

Abstract

Implantable cardioverter defibrillators (ICD) are capable of effectively terminating malignant ventricular arrhythmia and are the most effective way to prevent sudden cardiac death. However, some evidences demonstrated that both anti-tachycardia pacing (ATP) and ICD shock can also bring adverse prognosis. A 66-year-old Han Chinese man with prior ICD implantation was admitted to our hospital because of frequent ICD shocks. Although intravenous amiodarone and esmolol succinate were administered daily, the patient suffered 155 episodes of VT/VF during 8 weeks after implantation. After repeated discharge of the device, the pacing threshold of the patient increased gradually. Considering the inappropriate increase of the pacing threshold, we decided to reposition the right ventricular (RV) lead with good sensing and threshold parameters confirmed. Subsequent 22 months interrogation follow-up revealed a stable lead position and electrical specifications. Furthermore, antiarrhythmic drugs were maximally increased, while ATP burst was remarkably decreased and the inappropriate ICD shock never occurred until now. An inappropriate pacing threshold was increased secondary to repeated ICD electrical storm. A timely active lead position adjustment reduced the pacing threshold and eliminated the risk of premature battery depletion.

Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 11 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 11 100%

Demographic breakdown

Readers by professional status Count As %
Researcher 3 27%
Student > Ph. D. Student 2 18%
Student > Bachelor 1 9%
Student > Master 1 9%
Student > Postgraduate 1 9%
Other 0 0%
Unknown 3 27%
Readers by discipline Count As %
Medicine and Dentistry 2 18%
Nursing and Health Professions 2 18%
Environmental Science 1 9%
Biochemistry, Genetics and Molecular Biology 1 9%
Neuroscience 1 9%
Other 1 9%
Unknown 3 27%