↓ Skip to main content

Auxiliary diagnostic potential of ventricle geometry and late gadolinium enhancement in left ventricular non-compaction; non-randomized case control study

Overview of attention for article published in BMC Cardiovascular Disorders, December 2017
Altmetric Badge

Mentioned by

twitter
1 X user

Citations

dimensions_citation
11 Dimensions

Readers on

mendeley
14 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
Auxiliary diagnostic potential of ventricle geometry and late gadolinium enhancement in left ventricular non-compaction; non-randomized case control study
Published in
BMC Cardiovascular Disorders, December 2017
DOI 10.1186/s12872-017-0721-0
Pubmed ID
Authors

Marko Boban, Vladimir Pesa, Ivo Darko Gabric, Sime Manola, Viktor Persic, Helena Antic-Kauzlaric, Marinko Zulj, Aleksandar Vcev

Abstract

There are still ambiguities existing in regard to left ventricular non-compaction (LVNC) diagnostic imaging. The aim of our study was to analyze diagnostic potential of late gadolinium enhancement (LGE) and ventricle geometry in patients with LVNC and controls. Data on cardiac magnetic resonance imaging (CMR) studies for LVNC were reassessed from the hospital's database (3.75 years; n=1975 exams). Matching sample of controls included cases with no structural heart disease, hypertrophic or dilative cardiomyopathy, arrhythmogenic right ventricular dysplasia or subacute myocarditis. Eccentricity of the left ventricle was measured at end diastole in the region with pronounced NC and maximal to minimal ratio (MaxMinEDDR) was calculated. Study included 255 patients referred for CMR, 100 (39.2%) with LVNC (prevalence in the studied period 5.01%) and 155 (60.8%) controls. Existing LGE had sensitivity of 52.5% (95%-CI:42.3-62.5), specificity of 80.4% (95%-CI:73.2-86.5) for LVNC, area under curve (AUC) 0.664 (95%-CI:0.603-0.722);p<0.001. MaxMinEDDR>1.10 had sensitivity of 95.0% (95%-CI:88.7-98.4), specificity of 82.6% (95%-CI: 75.7-88.2) for LVNC, AUC 0.917 (95%-CI:0.876-0.948); p<0.001. LGE correlated with Max-Min-EDD-R (Rho=0.130; p=0.038) and there was significant difference in ROC analysis ΔAUC0.244 (95%-CI:0.175-0.314); p<0.001. LGE also correlated negatively with stroke volume and systolic function (both p<0.05, respectively). LGE was found to be frequently expressed in patients with LVNC, but without sufficient power to be used as a discriminative diagnostic parameter. Both LGE and eccentricity of the left ventricle were found to be relatively solid diagnostic landmarks of complex infrastructural and functional changes within the failing heart.

X Demographics

X Demographics

The data shown below were collected from the profile of 1 X user who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 14 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 14 100%

Demographic breakdown

Readers by professional status Count As %
Student > Bachelor 4 29%
Researcher 2 14%
Student > Postgraduate 2 14%
Student > Master 1 7%
Unspecified 1 7%
Other 2 14%
Unknown 2 14%
Readers by discipline Count As %
Medicine and Dentistry 6 43%
Unspecified 1 7%
Immunology and Microbiology 1 7%
Nursing and Health Professions 1 7%
Psychology 1 7%
Other 1 7%
Unknown 3 21%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 1. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 09 January 2018.
All research outputs
#18,578,649
of 23,011,300 outputs
Outputs from BMC Cardiovascular Disorders
#1,127
of 1,637 outputs
Outputs of similar age
#327,490
of 439,989 outputs
Outputs of similar age from BMC Cardiovascular Disorders
#8
of 12 outputs
Altmetric has tracked 23,011,300 research outputs across all sources so far. This one is in the 11th percentile – i.e., 11% of other outputs scored the same or lower than it.
So far Altmetric has tracked 1,637 research outputs from this source. They receive a mean Attention Score of 3.9. This one is in the 18th percentile – i.e., 18% of its peers scored the same or lower than it.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 439,989 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 14th percentile – i.e., 14% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 12 others from the same source and published within six weeks on either side of this one. This one is in the 16th percentile – i.e., 16% of its contemporaries scored the same or lower than it.