Associations between intraoperative ventilator settings during one-lung ventilation and postoperative pulmonary complications: a prospective observational study

Overview of attention for article published in BMC Anesthesiology, January 2018
Altmetric Badge

Mentioned by

twitter
3 X users

Citations

dimensions_citation
34 Dimensions

Readers on

mendeley
46 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
Associations between intraoperative ventilator settings during one-lung ventilation and postoperative pulmonary complications: a prospective observational study
Published in
BMC Anesthesiology, January 2018
DOI 10.1186/s12871-018-0476-x
Pubmed ID
Authors

Shuji Okahara, Kazuyoshi Shimizu, Satoshi Suzuki, Kenzo Ishii, Hiroshi Morimatsu

Abstract

The interest in perioperative lung protective ventilation has been increasing. However, optimal management during one-lung ventilation (OLV) remains undetermined, which not only includes tidal volume (VT) and positive end-expiratory pressure (PEEP) but also inspired oxygen fraction (FIO2). We aimed to investigate current practice of intraoperative ventilation during OLV, and analyze whether the intraoperative ventilator settings are associated with postoperative pulmonary complications (PPCs) after thoracic surgery. We performed a prospective observational two-center study in Japan. Patients scheduled for thoracic surgery with OLV from April to October 2014 were eligible. We recorded ventilator settings (FIO2, VT, driving pressure (ΔP), and PEEP) and calculated the time-weighted average (TWA) of ventilator settings for the first 2 h of OLV. PPCs occurring within 7 days of thoracotomy were investigated. Associations between ventilator settings and the incidence of PPCs were examined by multivariate logistic regression. We analyzed perioperative information, including preoperative characteristics, ventilator settings, and details of surgery and anesthesia in 197 patients. Pressure control ventilation was utilized in most cases (92%). As an initial setting for OLV, an FIO2 of 1.0 was selected for more than 60% of all patients. Throughout OLV, the median TWA FIO2 of 0.8 (0.65-0.94), VT of 6.1 (5.3-7.0) ml/kg, ΔP of 17 (15-20) cm H2O, and PEEP of 4 (4-5) cm H2O was applied. Incidence rate of PPCs was 25.9%, and FIO2 was independently associated with the occurrence of PPCs in multivariate logistic regression. The adjusted odds ratio per FIO2 increase of 0.1 was 1.30 (95% confidence interval: 1.04-1.65, P = 0.0195). High FIO2 was applied to the majority of patients during OLV, whereas low VT and slight degree of PEEP were commonly used in our survey. Our findings suggested that a higher FIO2 during OLV could be associated with increased incidence of PPCs.

X Demographics

X Demographics

The data shown below were collected from the profiles of 3 X users who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 46 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 46 100%

Demographic breakdown

Readers by professional status Count As %
Other 8 17%
Researcher 5 11%
Student > Master 5 11%
Student > Doctoral Student 5 11%
Professor 5 11%
Other 13 28%
Unknown 5 11%
Readers by discipline Count As %
Medicine and Dentistry 27 59%
Nursing and Health Professions 5 11%
Engineering 2 4%
Biochemistry, Genetics and Molecular Biology 1 2%
Computer Science 1 2%
Other 3 7%
Unknown 7 15%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 1. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 21 August 2018.
All research outputs
#15,489,831
of 23,018,998 outputs
Outputs from BMC Anesthesiology
#678
of 1,509 outputs
Outputs of similar age
#269,977
of 441,125 outputs
Outputs of similar age from BMC Anesthesiology
#19
of 32 outputs
Altmetric has tracked 23,018,998 research outputs across all sources so far. This one is in the 22nd percentile – i.e., 22% of other outputs scored the same or lower than it.
So far Altmetric has tracked 1,509 research outputs from this source. They receive a mean Attention Score of 3.1. This one is in the 43rd percentile – i.e., 43% of its peers scored the same or lower than it.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 441,125 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 29th percentile – i.e., 29% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 32 others from the same source and published within six weeks on either side of this one. This one is in the 21st percentile – i.e., 21% of its contemporaries scored the same or lower than it.