↓ Skip to main content

Quantification of plasmid DNA reference materials for Shiga toxin-producing Escherichia coli based on UV, HR-ICP-MS and digital PCR

Overview of attention for article published in BMC Chemistry, September 2016
Altmetric Badge

Mentioned by

patent
1 patent

Citations

dimensions_citation
15 Dimensions

Readers on

mendeley
57 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
Quantification of plasmid DNA reference materials for Shiga toxin-producing Escherichia coli based on UV, HR-ICP-MS and digital PCR
Published in
BMC Chemistry, September 2016
DOI 10.1186/s13065-016-0201-0
Pubmed ID
Authors

Wen Liang, Li Xu, Zhiwei Sui, Yan Li, Lanying Li, Yanli Wen, Chunhua Li, Shuzhen Ren, Gang Liu

Abstract

The accuracy and metrology traceability of DNA quantification is becoming a critical theme in many fields, including diagnosis, forensic analysis, microorganism detection etc. Thus the research of DNA reference materials (RMs) and consistency of DNA quantification methods has attracted considerable research interest. In this work, we developed 3 plasmid candidate RMs, containing 3 target genes of Escherichia coli O157:H7 (E. coli O157:H7) and other Shiga toxin-producing Escherichia coli (STEC): stx1, stx2, and fliC (h7) respectively. Comprehensive investigation of the plasmid RMs was performed for their sequence, purity, homogeneity and stability, and then the concentration was quantified by three different methods: ultraviolet spectrophotometer (UV), high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) and digital PCR. As a routinely applied method for DNA analysis, UV was utilized for the quantification (OD260) and purity analysis for the plasmids. HR-ICP-MS quantified the plasmid DNA through analysing the phosphorus in DNA molecules. Digital PCR distributed the DNA samples onto a microarray chip containing thousands of reaction chambers, and quantified the DNA copy numbers by analysing the number of positive signals without any calibration curves needed. Based on the high purification of the DNA reference materials and the optimization of dPCR analysis, we successfully achieved good consistency between UV, HR-ICP-MS and dPCR, with relative deviations lower than 10 %. We then performed the co-quantification of 3 DNA RMs with three different methods together, and the uncertainties of their concentration were evaluated. Finally, the certified values and expanded uncertainties for 3 DNA RMs (pFliC, pStx1 and pStx2) were (1.60 ± 0.10) × 10(10) copies/μL, (1.53 ± 0.10) × 10(10) copies/μL and (1.70 ± 0.11) × 10(10) copies/μL respectively.Graphical abstractWe developed 3 plasmid candidate RMs, containing 3 target genes of Escherichia coli O157:H7 (E. coli O157:H7) and other Shiga toxin-producing Escherichia coli (STEC): stx1, stx2, and fliC (h7) respectively, and the quantification of three different methods (UV, dPCR, ICP) was studied.

Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 57 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 57 100%

Demographic breakdown

Readers by professional status Count As %
Student > Bachelor 15 26%
Researcher 5 9%
Student > Master 5 9%
Student > Ph. D. Student 4 7%
Student > Postgraduate 4 7%
Other 9 16%
Unknown 15 26%
Readers by discipline Count As %
Biochemistry, Genetics and Molecular Biology 16 28%
Agricultural and Biological Sciences 7 12%
Chemistry 5 9%
Psychology 2 4%
Unspecified 2 4%
Other 8 14%
Unknown 17 30%