↓ Skip to main content

Comparative bench study evaluation of different infant interfaces for non-invasive ventilation

Overview of attention for article published in BMC Pulmonary Medicine, April 2018
Altmetric Badge

About this Attention Score

  • Average Attention Score compared to outputs of the same age and source

Mentioned by

twitter
2 X users

Citations

dimensions_citation
6 Dimensions

Readers on

mendeley
46 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
Comparative bench study evaluation of different infant interfaces for non-invasive ventilation
Published in
BMC Pulmonary Medicine, April 2018
DOI 10.1186/s12890-018-0620-x
Pubmed ID
Authors

Giorgio Conti, Giorgia Spinazzola, Cesare Gregoretti, Giuliano Ferrone, Andrea Cortegiani, Olimpia Festa, Marco Piastra, Luca Tortorolo, Roberta Costa

Abstract

To compare, in terms of patient-ventilator interaction and performance, a new nasal mask (Respireo, AirLiquide, FR) with the Endotracheal tube (ET) and a commonly used nasal mask (FPM, Fisher and Paykel, NZ) for delivering Pressure Support Ventilation (PSV) in an infant model of Acute Respiratory Failure (ARF). An active test lung (ASL 5000) connected to an infant mannequin through 3 different interfaces (Respireo, ET and FPM), was ventilated with a standard ICU ventilator set in PSV. The test lung was set to simulate a 5.5 kg infant with ARF, breathing at 50 and 60 breaths/min). Non-invasive ventilation (NIV) mode was not used and the leaks were nearly zero. The ET showed the shortest inspiratory trigger delay and pressurization time compared to FPM and Respireo (p < 0.01). At each respiratory rate tested, the FPM showed the shortest Expiratory trigger delay compared to ET and Respireo (p < 0.01). The Respireo presented a lower value of Inspiratory pressure-time product and trigger pressure drop than ET (p < 0.01), while no significant difference was found in terms of pressure-time product at 300 and 500 ms. During all tests, compared with the FPM, ET showed a significantly higher tidal volume (VT) delivered (p < 0.01), while Respireo showed a trend toward an increase of tidal volume delivered compared with FPM. The ET showed a better patient-ventilator interaction and performance compared to both the nasal masks. Despite the higher internal volume, Respireo showed a trend toward an increase of the delivered tidal volume; globally, its efficiency in terms of patient-ventilator interaction was comparable to the FPM, which is the infant NIV mask characterized by the smaller internal volume among the (few) models on the market.

X Demographics

X Demographics

The data shown below were collected from the profiles of 2 X users who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 46 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 46 100%

Demographic breakdown

Readers by professional status Count As %
Other 8 17%
Student > Master 8 17%
Researcher 4 9%
Professor > Associate Professor 3 7%
Student > Postgraduate 2 4%
Other 3 7%
Unknown 18 39%
Readers by discipline Count As %
Medicine and Dentistry 15 33%
Nursing and Health Professions 5 11%
Engineering 3 7%
Agricultural and Biological Sciences 2 4%
Business, Management and Accounting 1 2%
Other 2 4%
Unknown 18 39%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 1. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 09 April 2018.
All research outputs
#15,504,780
of 23,041,514 outputs
Outputs from BMC Pulmonary Medicine
#1,101
of 1,953 outputs
Outputs of similar age
#209,700
of 328,950 outputs
Outputs of similar age from BMC Pulmonary Medicine
#28
of 46 outputs
Altmetric has tracked 23,041,514 research outputs across all sources so far. This one is in the 22nd percentile – i.e., 22% of other outputs scored the same or lower than it.
So far Altmetric has tracked 1,953 research outputs from this source. They typically receive a little more attention than average, with a mean Attention Score of 5.4. This one is in the 34th percentile – i.e., 34% of its peers scored the same or lower than it.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 328,950 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 27th percentile – i.e., 27% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 46 others from the same source and published within six weeks on either side of this one. This one is in the 34th percentile – i.e., 34% of its contemporaries scored the same or lower than it.