↓ Skip to main content

Highly sensitive and accurate detection of C-reactive protein by CdSe/ZnS quantum dot-based fluorescence-linked immunosorbent assay

Overview of attention for article published in Journal of Nanobiotechnology, May 2017
Altmetric Badge

Citations

dimensions_citation
68 Dimensions

Readers on

mendeley
52 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
Highly sensitive and accurate detection of C-reactive protein by CdSe/ZnS quantum dot-based fluorescence-linked immunosorbent assay
Published in
Journal of Nanobiotechnology, May 2017
DOI 10.1186/s12951-017-0267-4
Pubmed ID
Authors

Yanbing Lv, Ruili Wu, Kunrui Feng, Jinjie Li, Qing Mao, Hang Yuan, Huaibin Shen, Xiangdong Chai, Lin Song Li

Abstract

The conventional and widely used enzyme-linked immunosorbent assays (ELISA), due to specificity and high-sensitivity, were suitable in vitro diagnosis. But enzymes are vulnerable to the external conditions, and the complex operation steps limit its application. Semiconductor quantum dots have been successfully used in biological and medical research due to the high photoluminescence and high resistance to photobleaching. In this study, we have developed a novel quantum dot-labeled immunosorbent assay for rapid disease detection of C-reactive protein (CRP). The assay for the detection of CRP can provide a wide analytical range of 1.56-400 ng/mL with the limit of detection (LOD) = 0.46 ng/mL and the limit of quantification = 1.53 ng/mL. The precision of the assay has been confirmed for low coefficient of variation, less than 10% (intra-assay) and less than 15% (inter-assay). The accuracy of assay meets the requirements with the recoveries of 95.4-105.7%. Furthermore, clinical samples have been collected and used for correlation analysis between this FLISA and gold standard Roche immunoturbidimetry. It shows excellent accurate concordance and the correlation coefficient value (R) is as high as 0.989 (n = 34). This in vitro quantum dot-based detection method offers a lower LOD and a wide liner detection range than ELISA. The total reaction time is only 50 min, which is much shorter than the commercialization ELISA (about 120 min). All of the results show that a convenient, sensitive, and accurate fluorescence-linked immunosorbent assay method has been well established for the detection of CRP samples. Therefore, this method has immense potential for the development of rapid and cost-effective in vitro diagnostic kits.

Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 52 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 52 100%

Demographic breakdown

Readers by professional status Count As %
Student > Ph. D. Student 9 17%
Student > Master 9 17%
Researcher 5 10%
Lecturer > Senior Lecturer 3 6%
Student > Postgraduate 2 4%
Other 7 13%
Unknown 17 33%
Readers by discipline Count As %
Biochemistry, Genetics and Molecular Biology 7 13%
Chemistry 7 13%
Materials Science 3 6%
Medicine and Dentistry 3 6%
Engineering 3 6%
Other 10 19%
Unknown 19 37%