↓ Skip to main content

Effective prevention of pseudothrombocytopenia in feline blood samples with the prostaglandin I2 analogue Iloprost

Overview of attention for article published in BMC Veterinary Research, August 2015
Altmetric Badge

About this Attention Score

  • Good Attention Score compared to outputs of the same age (71st percentile)
  • High Attention Score compared to outputs of the same age and source (81st percentile)

Mentioned by

twitter
2 X users
patent
1 patent

Readers on

mendeley
13 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
Effective prevention of pseudothrombocytopenia in feline blood samples with the prostaglandin I2 analogue Iloprost
Published in
BMC Veterinary Research, August 2015
DOI 10.1186/s12917-015-0510-x
Pubmed ID
Authors

Barbara Riond, Andrea Katharina Waßmuth, Sonja Hartnack, Regina Hofmann-Lehmann, Hans Lutz

Abstract

In vitro platelet aggregation in feline blood samples is a well-known phenomenon in veterinary clinical laboratories resulting in high numbers of pseudothrombocytopenia. Several attempts have been made to prevent or dissolve platelet aggregates in feline blood samples and to increase the reliability of feline platelet counts. Prostaglandin I2 (PGI2) is the most powerful endogenous inhibitor of platelet aggregation but unstable. Iloprost is a stable PGI2 analogue. The aims of the present study were (1) to evaluate the anti-aggregatory effect of Iloprost on feline platelet counts and to determine a useful concentration to inhibit platelet aggregation in EDTA samples from clinically healthy cats, (2) to investigate the effect of Iloprost on hematological blood parameters, and (3) to determine stability of Iloprost in K3-EDTA tubes for up to 16 weeks. From 20 clinically healthy cats blood was drawn from the jugular vein and immediately distributed in a 1.3 ml K3-EDTA tube, and two 1.3 ml K3-EDTA tubes containing 20 ng and 200 ng Iloprost, respectively. A complete blood cell count was performed on the Sysmex XT-2000iV and the Mythic 18 on eight consecutive time points after collection. Blood smears were evaluated for the presence of PLT aggregates. In the absence of Iloprost, pseudothrombocytopenia was observed in 50 % of the investigated samples that led to significantly decreased optical PLT counts by a mean of 105 x10(3)/μl, which could be prevented by the addition of 1 μL (20 ng) Iloprost leading to an increase in PLT counts by a mean of 108 x10(3)/μl. This is the first study showing an anti-aggregatory effect of the PGI2-analogue Iloprost in feline EDTA blood. In all clinically healthy cats investigated, pseudothrombocytopenia was prevented by adding Iloprost to EDTA tubes prior to blood collection. Furthermore, Iloprost was very useful in preventing falsely increased WBC counts in samples with platelet aggregates analyzed on impedance-based hematological instruments. Iloprost is preferable to PGI2 or PGE1 due to its stability and easy and safe handling properties. Cytological evaluations of blood smears as well as other hematological parameters were not influenced to a clinically significant degree by the presence of Iloprost.

X Demographics

X Demographics

The data shown below were collected from the profiles of 2 X users who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 13 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 13 100%

Demographic breakdown

Readers by professional status Count As %
Researcher 4 31%
Student > Doctoral Student 1 8%
Student > Ph. D. Student 1 8%
Professor 1 8%
Student > Master 1 8%
Other 1 8%
Unknown 4 31%
Readers by discipline Count As %
Veterinary Science and Veterinary Medicine 5 38%
Medicine and Dentistry 4 31%
Unknown 4 31%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 5. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 30 June 2022.
All research outputs
#6,358,223
of 22,764,165 outputs
Outputs from BMC Veterinary Research
#470
of 3,043 outputs
Outputs of similar age
#74,268
of 263,970 outputs
Outputs of similar age from BMC Veterinary Research
#14
of 75 outputs
Altmetric has tracked 22,764,165 research outputs across all sources so far. This one has received more attention than most of these and is in the 71st percentile.
So far Altmetric has tracked 3,043 research outputs from this source. They receive a mean Attention Score of 3.8. This one has done well, scoring higher than 84% of its peers.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 263,970 tracked outputs that were published within six weeks on either side of this one in any source. This one has gotten more attention than average, scoring higher than 71% of its contemporaries.
We're also able to compare this research output to 75 others from the same source and published within six weeks on either side of this one. This one has done well, scoring higher than 81% of its contemporaries.