↓ Skip to main content

Intraoperative 3D imaging in the treatment of elbow fractures - a retrospective analysis of indications, intraoperative revision rates, and implications in 36 cases

Overview of attention for article published in BMC Medical Imaging, March 2016
Altmetric Badge

Mentioned by

twitter
1 X user

Citations

dimensions_citation
18 Dimensions

Readers on

mendeley
30 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
Intraoperative 3D imaging in the treatment of elbow fractures - a retrospective analysis of indications, intraoperative revision rates, and implications in 36 cases
Published in
BMC Medical Imaging, March 2016
DOI 10.1186/s12880-016-0126-z
Pubmed ID
Authors

Marc Schnetzke, Julia Fuchs, Sven Y. Vetter, Nils Beisemann, Holger Keil, Paul-Alfred Grützner, Jochen Franke

Abstract

Three-dimensional (3D) imaging with a mobile C-arm has proven to be a valuable intraoperative tool in trauma surgery. However, little data is available concerning its use in the treatment of elbow fractures. The aim of the current study was to determine the intraoperative findings and consequences of 3D imaging in the treatment of elbow fractures. Between 2001 and 2015, prospectively collected data of 36 patients who underwent intraoperative 3D imaging during elbow surgery were recorded. The findings and consequences of the intraoperative 3D scans were analyzed in a retrospective chart review. For clinical evaluation the analysis included the patients' medical history, the injury pattern of the affected elbow and concomitant injuries. Intraoperative and postoperative complications and revision surgeries were evaluated as well. In 6 patients (16.7 %) analysis of the intraoperative 3D scan led to an immediate revision due to the detection of intra-articular screw placement (n = 3, 8.3 %) and remaining intra-articular step of >2 mm (n = 3, 8.3 %). In all of these patients, correct implant positioning and anatomical reduction could be achieved after immediate intraoperative revision, which was verified by a repeated intraoperative 3D scan. None of the 36 patients needed surgical revision based on postoperative radiological examinations due to secondary dislocation, wrong implant placement or remaining steps in the articular surface. Intraoperative 3D imaging offers additional information about fracture reduction and implant positioning in the treatment of elbow fractures compared to conventional intraoperative 2D imaging. It may therefore reduce the need for revision surgery. The value of intraoperative 3D imaging for clinical outcomes still needs to be assessed.

X Demographics

X Demographics

The data shown below were collected from the profile of 1 X user who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 30 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 30 100%

Demographic breakdown

Readers by professional status Count As %
Researcher 5 17%
Student > Master 5 17%
Other 3 10%
Student > Ph. D. Student 3 10%
Student > Doctoral Student 2 7%
Other 3 10%
Unknown 9 30%
Readers by discipline Count As %
Medicine and Dentistry 12 40%
Nursing and Health Professions 2 7%
Computer Science 1 3%
Social Sciences 1 3%
Engineering 1 3%
Other 0 0%
Unknown 13 43%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 1. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 19 March 2016.
All research outputs
#21,264,673
of 23,881,329 outputs
Outputs from BMC Medical Imaging
#461
of 604 outputs
Outputs of similar age
#260,993
of 303,302 outputs
Outputs of similar age from BMC Medical Imaging
#12
of 12 outputs
Altmetric has tracked 23,881,329 research outputs across all sources so far. This one is in the 1st percentile – i.e., 1% of other outputs scored the same or lower than it.
So far Altmetric has tracked 604 research outputs from this source. They receive a mean Attention Score of 2.1. This one is in the 1st percentile – i.e., 1% of its peers scored the same or lower than it.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 303,302 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 1st percentile – i.e., 1% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 12 others from the same source and published within six weeks on either side of this one. This one is in the 1st percentile – i.e., 1% of its contemporaries scored the same or lower than it.