↓ Skip to main content

Custom-designed orthopedic implants evaluated using finite element analysis of patient-specific computed tomography data: femoral-component case study

Overview of attention for article published in BMC Musculoskeletal Disorders, September 2007
Altmetric Badge

About this Attention Score

  • In the top 25% of all research outputs scored by Altmetric
  • Good Attention Score compared to outputs of the same age (78th percentile)

Mentioned by

news
1 news outlet

Citations

dimensions_citation
166 Dimensions

Readers on

mendeley
267 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
Custom-designed orthopedic implants evaluated using finite element analysis of patient-specific computed tomography data: femoral-component case study
Published in
BMC Musculoskeletal Disorders, September 2007
DOI 10.1186/1471-2474-8-91
Pubmed ID
Authors

Ola LA Harrysson, Yasser A Hosni, Jamal F Nayfeh

Mendeley readers

The data shown below were compiled from readership statistics for 267 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
United States 3 1%
Germany 2 <1%
Netherlands 2 <1%
United Kingdom 1 <1%
Brazil 1 <1%
Japan 1 <1%
Ukraine 1 <1%
Unknown 256 96%

Demographic breakdown

Readers by professional status Count As %
Student > Ph. D. Student 51 19%
Student > Master 45 17%
Researcher 34 13%
Student > Bachelor 27 10%
Student > Postgraduate 16 6%
Other 54 20%
Unknown 40 15%
Readers by discipline Count As %
Engineering 111 42%
Medicine and Dentistry 54 20%
Materials Science 6 2%
Computer Science 5 2%
Design 5 2%
Other 29 11%
Unknown 57 21%

Attention Score in Context

This research output has an Altmetric Attention Score of 7. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 03 May 2016.
All research outputs
#1,907,891
of 12,373,620 outputs
Outputs from BMC Musculoskeletal Disorders
#430
of 2,454 outputs
Outputs of similar age
#54,880
of 268,383 outputs
Outputs of similar age from BMC Musculoskeletal Disorders
#1
of 2 outputs
Altmetric has tracked 12,373,620 research outputs across all sources so far. Compared to these this one has done well and is in the 83rd percentile: it's in the top 25% of all research outputs ever tracked by Altmetric.
So far Altmetric has tracked 2,454 research outputs from this source. They typically receive a little more attention than average, with a mean Attention Score of 5.8. This one has done well, scoring higher than 81% of its peers.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 268,383 tracked outputs that were published within six weeks on either side of this one in any source. This one has done well, scoring higher than 78% of its contemporaries.
We're also able to compare this research output to 2 others from the same source and published within six weeks on either side of this one. This one has scored higher than all of them