↓ Skip to main content

Selective laser melting of titanium alloy enables osseointegration of porous multi-rooted implants in a rabbit model

Overview of attention for article published in BioMedical Engineering OnLine, July 2016
Altmetric Badge

About this Attention Score

  • Average Attention Score compared to outputs of the same age
  • Above-average Attention Score compared to outputs of the same age and source (52nd percentile)

Mentioned by

twitter
1 X user
facebook
1 Facebook page

Citations

dimensions_citation
39 Dimensions

Readers on

mendeley
99 Mendeley
You are seeing a free-to-access but limited selection of the activity Altmetric has collected about this research output. Click here to find out more.
Title
Selective laser melting of titanium alloy enables osseointegration of porous multi-rooted implants in a rabbit model
Published in
BioMedical Engineering OnLine, July 2016
DOI 10.1186/s12938-016-0207-9
Pubmed ID
Authors

Wei Peng, Liangwei Xu, Jia You, Lihua Fang, Qing Zhang

Abstract

Osseointegration refers to the direct connection between living bone and the surface of a load-bearing artificial implant. Porous implants with well-controlled porosity and pore size can enhance osseointegration. However, until recently implants were produced by machining solid core titanium rods. The aim of this study was to develop a multi-rooted dental implant (MRI) with a connected porous surface structure to facilitate osseointegration. MRIs manufactured by selective laser melting (SLM) and commercial implants with resorbable blasting media (RBM)-treated surfaces were inserted into the hind limbs of New Zealand white rabbits. Osseointegration was evaluated periodically over 12 weeks by micro-computerized tomography (CT) scanning, histological analysis, mechanical push-out tests, and torque tests. Bone volume densities were consistently higher in the MRI group than in the RBM group throughout the study period, ultimately resulting in a peak value of 48.41 % for the MRI group. Histological analysis revealed denser surrounding bone growth in the MRIs; after 4 and 8 weeks, bone tissue had grown into the pore structures and root bifurcation areas, respectively. Biomechanics tests indicated binding of the porous MRIs to the neobone tissues, as push-out forces strengthened from 294.7 to 446.5 N and maximum mean torque forces improved from 81.15 to 289.57 N (MRI), versus 34.79 to 87.8 N in the RBM group. MRIs manufactured by SLM possess a connected porous surface structure that improves the osteogenic characteristics of the implant surface.

X Demographics

X Demographics

The data shown below were collected from the profile of 1 X user who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 99 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 99 100%

Demographic breakdown

Readers by professional status Count As %
Student > Master 14 14%
Student > Bachelor 13 13%
Student > Ph. D. Student 10 10%
Researcher 9 9%
Professor > Associate Professor 6 6%
Other 20 20%
Unknown 27 27%
Readers by discipline Count As %
Medicine and Dentistry 24 24%
Engineering 22 22%
Materials Science 14 14%
Business, Management and Accounting 1 1%
Nursing and Health Professions 1 1%
Other 6 6%
Unknown 31 31%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 2. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 23 July 2016.
All research outputs
#16,722,913
of 25,374,917 outputs
Outputs from BioMedical Engineering OnLine
#429
of 867 outputs
Outputs of similar age
#239,160
of 378,817 outputs
Outputs of similar age from BioMedical Engineering OnLine
#10
of 23 outputs
Altmetric has tracked 25,374,917 research outputs across all sources so far. This one is in the 32nd percentile – i.e., 32% of other outputs scored the same or lower than it.
So far Altmetric has tracked 867 research outputs from this source. They typically receive a little more attention than average, with a mean Attention Score of 5.3. This one is in the 47th percentile – i.e., 47% of its peers scored the same or lower than it.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 378,817 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 34th percentile – i.e., 34% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 23 others from the same source and published within six weeks on either side of this one. This one has gotten more attention than average, scoring higher than 52% of its contemporaries.